Exportar este item: EndNote BibTex

Use este identificador para citar ou linkar para este item: http://www.bdtd.uerj.br/handle/1/11531
Tipo do documento: Dissertação
Título: Estudo da aderência de barras de aço coladas ao concreto com resina Epóxi.
Título(s) alternativo(s): Study of bond behavior between reinforced bar and concrete with epoxi resin.
Autor: Fernandes, Dennis Videira 
Primeiro orientador: Tavares, Maria Elizabeth da Nóbrega
Primeiro coorientador: Souza, Regina Helena Ferreira de
Primeiro membro da banca: Shehata, Lídia da Conceição Domingues
Segundo membro da banca: Carneiro, Luiz Antonio Vieira
Terceiro membro da banca: Goulart, Evandro da Silveira
Resumo: Assim como em outras áreas do conhecimento a construção civil vem evoluindo ao longo dos anos. Grandes investimentos e elevadas taxas de demandas por novos projetos requerem uma maior velocidade na consolidação de obras. Neste cenário, ficam precários os estudos e pesquisas que avaliam a capacidade de novas tecnologias. Na área do concreto e estruturas de concreto armado, depara-se a associação de técnicas consolidadas à métodos inovadores. A utilização de polímeros como material de construção, como é o caso dos aditivos para concreto, dos tubos e conexões, das esquadrias e como adesivos, utilizados em ligações de aduelas de pontes, associados a fibras de vidro ou carbono para reforços estruturais e para fixação de armaduras ou conectores no caso de reparação de estruturas, oferecendo uma solidarização eficiente entre elementos estruturais. O presente trabalho visa avaliar uma pequena parcela de aplicação de materiais poliméricos, principalmente quanto a sua característica de aderência e colagem de barras de aço ao concreto. O desenvolvimento do estudo ocorreu sobre uma perspectiva de ensaios laboratoriais de arrancamento de barras coladas com resina epóxi em blocos de concreto, sendo estes resultados comparados com barras de aço concretadas em blocos de concreto. Desse modo o principal fator de comparação seria a tensão de aderência desenvolvida na área de contato da barra com o substrato. Alguns parâmetros foram inseridos para uma abordagem de maior amplitude, tais como variação do diâmetro da barra (φ = 10,0mm; φ = 12,5mm e φ = 16,0mm), do comprimento de ancoragem (múltiplos do diâmetro, sendo 5φ e 7,5φ) e da espessura da resina (1mm, 2mm e 3mm). De forma complementar procedeu-se ao ensaio de vigas bi-apoiadas submetidas à flexão visando representar o comportamento de uma recuperação/reforço estrutural aplicado em escala. Para avaliar o comportamento destas vigas, foram ensaiados dois espécimes, uma viga padrão concretada de uma única vez e outra submetida a um reparo estrutural, onde possuía a armadura inferior inserida posteriormente à concretagem inicial, colada com resina epóxi nas extremidades da viga.
Abstract: Just like others fields of knowledge, the civil construction is evolving. Hughes investments and the need for new projects improve the speed and the technology usually applied for basic infrastructure s development. These scenarios achieve issues as the miss understanding of the behavior of this technological advances in long terms, caused by the few studies and researches about these subjects. At the concrete structures field, an extremely self consolidate knowledge whose have been replaced for new methods, as the case of the polymeric materials. This kind of material have large scale of applications at construction and projects of structural elements, used as a bond interface for different elements and offering a significant monolithically performance between structural pieces. The current study pretends analyze the behavior of bonded steel bars at the concrete using epoxy resin. The development of the study occur by lab tests where a steel bar is pulled out of a concrete block, named Pull-out-test. This one was adapted for a bond whit epoxy resin, were the results was compared whit the regular ones (concrete bonded bars), in this method the phenomenon of the stress occurred at the bar surface in contact whit the concrete or the resin evaluate. Some parameters were included for a better understanding of the bond behavior, such as: Steel bar diameter (10mm, 12,5mm and 16mm); Length of anchorage (5φ and 7,5φ), and Resin thickness (1mm, 2mm and 3mm). For the same purpose, was molded a concrete beam to represent the bonded situation at a real condition, these beam had two different configuration, one of those were a regular reinforcement beam, and the other one were a recuperated reinforcement beam, whit yours inferior steel bar added post concrete solidification, simulating a intervention at a problematic beam, in this case the steel bars were bonded whit epoxy resin at the edges of the beam.
Palavras-chave: Pull-out-test
Bonded
Epoxy resin
Concrete structures
Structural recuperation
Ensaio de arrancamento
Aderência
Resina Epóxi
Estruturas de concreto
Recuperação estrutural
Área(s) do CNPq: CNPQ::ENGENHARIAS::ENGENHARIA CIVIL
Idioma: por
País: BR
Instituição: Universidade do Estado do Rio de Janeiro
Sigla da instituição: UERJ
Departamento: Centro de Tecnologia e Ciências::Faculdade de Engenharia
Programa: Programa de Pós-Graduação em Engenharia Civil
Citação: FERNANDES, Dennis Videira. Estudo da aderência de barras de aço coladas ao concreto com resina Epóxi.. 2011. 162 f. Dissertação (Mestrado em Estruturas; Geotecnia; Construção Civil) - Universidade do Estado do Rio de Janeiro, Rio de Janeiro, 2011.
Tipo de acesso: Acesso Aberto
URI: http://www.bdtd.uerj.br/handle/1/11531
Data de defesa: 25-Mar-2011
Aparece nas coleções:Mestrado em Engenharia Civil

Arquivos associados a este item:
Arquivo TamanhoFormato 
Dennis Videira Fernandes.pdf4,07 MBAdobe PDFBaixar/Abrir Pré-Visualizar


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.