Exportar este item: EndNote BibTex

Use este identificador para citar ou linkar para este item: http://www.bdtd.uerj.br/handle/1/16336
Tipo do documento: Tese
Título: Desenvolvimento e validação de metodologia por UPLC-MS/MS para determinação de produtos farmacêuticos, produtos de cuidados pessoais e desreguladores endócrinos na bacia hidrográfica do rio Guandu - RJ
Título(s) alternativo(s): Development and validation of UPLC-MS/MS methodology for the determination of pharmaceuticals, personal care products and endocrine disrupters in the Guandu river basin-RJ
Autor: Araujo, Frederico Goytacazes de 
Primeiro orientador: Martins, Eduardo Monteiro
Primeiro coorientador: Gomes, Marcia Marques
Primeiro membro da banca: Martins, Eduardo Monteiro
Segundo membro da banca: Gomes, Marcia Marques
Terceiro membro da banca: Marques, Mônica Regina da Costa
Quarto membro da banca: Lima, Juliana Fonseca de
Quinto membro da banca: Raices, Renata Santana Lorenzo
Resumo: Produtos farmacêuticos e de cuidados pessoais (PPCPs - do inglês Pharmaceuticals and Personal Care Products) e desreguladores endócrinos (EDs - do inglês Endocrine Disruptors) são micropoluentes presentes em concentrações que variam de ng L-1 a µg L-1, potencialmente perigosos para o ambiente bem como para humanos. Entre os PPCPs, amplamente consumidos encontram-se: Trimetoprim (TMP), Bromazepam (BZP), Clonazepam (CZP), Diazepam (DZP), Ibuprofeno (IBP) e Benzofenona (BEN). Os EDs, por sua vez, são substâncias que prejudicam o funcionamento normal do sistema endócrino. Entre eles estão o 4-Nonilfenol (4NP), Bisfenol A (BPA) e Dietiftalato (DEP). O método analítico utilizou a extração em fase sólida (SPE - do inglês Solid Phase Extraction) como preparo de amostra e determinação por Cromatografia Líquida de Ultra Eficiência acoplada à Espectrometria de Massas sequencial (UPLC-MS/MS - do inglês Ultra Perfomance Liquid Chromatography coupled to Mass Spectrometry tandem). Para a SPE utilizou-se cartuchos C18 - 500 mg, e eluição em duas etapas de 2,5 mL de metanol. Após a otimização da extração e da separação cromatográfica, o método analítico foi validado utilizando-se os parâmetros de validação da Agência de Proteção Ambiental dos Estados Unidos (USEPA - do inglês United States Environmental Protection Agency) dispostos no guia 8000D. O método desenvolvido foi sensível, robusto e seletivo. Os LDs e os LQs para o método variaram entre 0,844 e 8,13 ng L-1 para o LD e 10,0 e 50,0 ng L-1 para LQ; Os valores de precisão (%DPR) e exatidão ficaram dentro dos valores preconizados pelo guia USEPA 8000D (DPR < 20%) e exatidão entre (50 e 120%). Todas as curvas analíticas apresentaram valores de R2 > 0,990. Para o 4NP, BPA, CZP, DEP, IBP e TMP, foi evidenciado o efeito de matriz. O método validado foi aplicado nas amostras de água superficiais coletadas em Nova Iguaçu (NIG), Paracambi (PBI), Rio de Janeiro (RIO) e Seropédica (SER), entre os meses de abril/2018 e março/2019. Foi possível detectar todos os analitos em todas as amostras coletadas. Em SER, foi quantificado DEP e BPA em 100% das amostras. Em NIG, PBI e RIO foi quantificado DEP e BZP em 100% das amostras. Entretanto, outros analitos apresentaram alto percentual de quantificação, como por exemplo, IBP 91% em NIG, BPA 91% em PBI, DZP 82% no RIO e 82% de BPA em SER. A avaliação de risco evidenciou que o BPA e DZP apresentaram coeficientes de risco (RQ) alto (RQ>1) na bacia hidrográfica do Rio Guandu. Para a concentração ambiental medida (MEC - do inglês Measured Environmental Concentrations), o BPA apresentou RQ de 0,92. Todas as amostras apresentaram efeito de toxicidade aguda, através do teste de Dunnett, todas as amostras foram consideradas como tóxicas, com exceção da uma amostra (PBI – Out/2018). Todas as amostras coletadas apresentaram atividade estrogênica. Uma amostra de PBI apresentou um valor de equivalente de 17β-Estradiol (EQ-E2) aproximadamente 6 vezes superior ao valor de referência (1,00 ng L-1).
Abstract: Pharmaceuticals and personal care products (PPCPs) and endocrine disruptors (EDs) are micropollutants present in tests using µg L-1 and ng L-1, which are potentially dangerous for the environment as well as for humans. Among the PPCPs, widely consumed in themselves: Trimethoprim (TMP), Bromazepam (BZP), Clonazepam (CZP), Diazepam (DZP), Ibuprofen (IBP) and Benzophenone (BEN). EDs, in turn, are substances that impair the normal functioning of the endocrine system. Among them are 4-Nonylphenol (4NP), Bisphenol A (BPA) and Diethylphthalatee (DEP). The analytical method used for Solid Phase Extraction (SPE) as sample preparation and determination by Ultra Efficiency Liquid Chromatography coupled to Mass Spectrometry tandem (UPLC-MS/MS). For an SPE, use C18 - 500 mg cartridges and elution in two steps of 2.50 mL of methanol. After the optimization of the extraction and chromatographic separation, the analytical method was validated, using the validation parameters of United States Environmental Protection Agency (USEPA) according 8000D guide. The method developed was, sensitive, robust and selected. The LODs and LOQs for the method, varying between 0.844 and 8.13 from L-1 for LOD and 10.0 and 50.0 ng L-1 for LOQ; The precision values (% RSD) and the accuracy remain within the values recommended by the USEPA 8000D guide (RSD <20%) and accuracy between 50 and 120%. All analytical curves show values of R2> 0.990. For the 4NP, BPA, CZP, DEP, IBP and TMP, matrix effect was evidenced. The method was applied to surface water bottles collected in Nova Iguaçu (NIG), Paracambi (PBI), Rio de Janeiro (RIO) and Seropédica (SER), between April/2018 and March/2019. It was possible to detect all analytes in all collected samples. In the SER, DEP and BPA were quantified in 100% of the specifications. In PBI, SER and RIO, DEP and BZP were quantified in 100% of the colors. However, other analytes showed a high percentage of quantification, for example, IBP 91% in NIG, BPA 91% in PBI, DZP 82% in RIO and 82% in BPA in SER. A risk assessment evidenced by the BPA and DZP micropollutants shows high high risk coefficient (RQ > 1) in the Guandu River basin. For Minimum Environmental Concentration (MEC), BPA presented an RQ of 0.92. All samples showed an acute toxicity effect, through the Dunnett test, all samples were considered toxic, except for one sample (PBI - Oct / 2018). All samples collected showed estrogenic activity. A PBI sample showed an equivalent value of 17β-Estradiol (EQ-E2) approximately 6 times higher than the reference value (1.00 ng L-1).
Palavras-chave: Desenvolvimento de método analítico
Desregulares Endócrinos
PPCPs
UPLC-MS/MS
Rio Guandu
Development of analytical method
Endocrine disruptors
Guandu River
Água - Qualidade
Água - Poluição
Rio Guandu (RJ)
Área(s) do CNPq: CIENCIAS EXATAS E DA TERRA::QUIMICA::QUIMICA ANALITICA::ANALISE DE TRACOS E QUIMICA AMBIENTAL
Idioma: por
País: Brasil
Instituição: Universidade do Estado do Rio de Janeiro
Sigla da instituição: UERJ
Departamento: Centro de Tecnologia e Ciências::Instituto de Química
Programa: Programa de Pós-Graduação em Química
Citação: ARAUJO, Frederico Goytacazes de. Desenvolvimento e validação de metodologia por UPLC-MS/MS para determinação de produtos farmacêuticos, produtos de cuidados pessoais e desreguladores endócrinos na bacia hidrográfica do rio Guandu - RJ. 2020. 188 f. Tese (Doutorado em Química) - Faculdade de Química, Universidade do Estado do Rio de Janeiro, Rio de Janeiro, 2020.
Tipo de acesso: Acesso Aberto
URI: http://www.bdtd.uerj.br/handle/1/16336
Data de defesa: 9-Jun-2020
Aparece nas coleções:Doutorado em Química

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
Tese - Frederico Goytacazes de Araujo - 2020 - Completa.pdf6,46 MBAdobe PDFBaixar/Abrir Pré-Visualizar


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.