Título: | Identificação de não conformidades pré-analíticas do laboratório de patologia clínica do Hospital do Câncer I |
Título(s) alternativo(s): | Identification of Pre-analytical Nonconformities of the Clinical Pathology Laboratory of Hospital do Câncer I |
Autor: | Ferreira, Raphael Gialluisi da Silva Sá ![]() |
Primeiro orientador: | Hamer, Erica Ripoll |
Primeiro membro da banca: | Neufeld, Paulo Murillo |
Segundo membro da banca: | Mello, Cintia Xavier de |
Resumo: | O exame laboratorial é dividido em três fases: pré-analítica, analítica e pós-analítica, sendo que a fase pré-analítica é a de maior incidência de erros no processo de realização de um exame laboratorial. O serviço de patologia clínica do Hospital do Câncer I não realizava o rastreamento dos indicadores de erros no processo de realização dos exames. O laboratório processou mais de 220 mil amostras, com um volume aproximado de 1,8 milhão de exames no ano de 2019. Considerando o volume de amostras processadas, tornou-se fundamental, para a segurança dos pacientes e garantir a qualidade do serviço prestado, o rastreamento dos erros que mais ocorrem nesta instituição. Mediante este preceito, este estudo teve como objetivo rastrear os principais erros no processo da fase pré-analítica do Laboratório de Patologia Clínica do Hospital do Câncer I, realizar o benchmarking dos dados obtidos com os resultados do estudo brasileiro PBIL - Programa de Benchmarking e Indicadores Laboratoriais/SBPC e do estudo internacional coordenado pela IFCC (Federação Internacional de Química Clínica) e elaborar um Manual de Ações para evitar repetições desses mesmos erros na rotina de trabalho . Foram 14 os indicadores pertencentes a fase pré-analítica rastreados, utilizando os dados contidos no sistema LIS do Laboratório. Os dados foram prospectados de dois setores, Imunoquímica e Hematologia, os quais tem um padrão de relato nos erros encontrados e produzem cerca de 75% das amostras processadas pelo laboratório. Estes dados foram utilizados para calcular o percentual de ocorrência, DPMO e SIGMA de cada um dos indicadores. A partir destes cálculos foi realizado o benchmarking com outros dois estudos: PBIL (SBPC e Controllab) e IFCC (grupo de trabalho de segurança do paciente e erros laboratoriais). Foram rastreados 5.541 erros no total dos 14 indicadores, sendo que 12 destes indicadores do Instituto Nacional de Câncer (INCA) apresentavam, no ano de 2019, um comportamento superior ou igual, quando comparados com os outros dois estudos (PBIL e IFCC). A hemólise e a formação de fibrina após a centrifugação, foram os indicadores com os piores comportamentos e devem ter um foco maior para a correção pelas equipes do laboratório envolvidas neste processo. Foi elaborado o Manual de Gerenciamento de Erros Pré-analíticos com o intuito de normatizar os processos e melhorar os indicadores abaixo do nível desejado e manter a qualidade dos indicadores que estão em níveis minimamente aceitáveis. O contínuo acompanhamento, abrangência de todo os setores do laboratório e ampliação dos indicadores rastreados é fundamental para a garantia da qualidade do serviço prestado do laboratório e a segurança do paciente. |
Abstract: | The laboratory exam is divided into three phases: pre-analytical, analytical and post-analytical, with the pre-analytical phase having the highest incidence of errors in the process of performing a laboratory exam. The clinical pathology service at the Cancer Hospital I, did not track the indicators of errors in the process of performing the tests. The laboratory processed more than 220,000 samples, with an approximate volume of 1.8 million tests in the year 2019.Considering the volume of samples processed, it has become essential for patient safety and to ensure the quality of the service provided, to track the errors that occur most in this institution. Based on this precept, this study aimed to track the main errors in the process of the pre-analytical phase of the clinical pathology laboratory of the Hospital do Câncer I, perform a benchmarking of the data obtained from the results of the Brazilian study PBIL- Benchmarking and Laboratory Indicators Program/SBPC and the international study coordinated by the IFCC (International Federation of Clinical Chemistry) and elaborate an Actions Manual to avoid the repetition of these same errors in the work routine. There were 14 indicators belonging to the pre-analytical phase that were tracked, using the data contained in the LIS system used in the Laboratory. Data were prospected from two sectors, Immunochemistry and Hematology, which had a pattern of reporting errors found and produce about 75% of the samples processed by the laboratory. Based on these data, the percentage of occurrence, DPMO and SIGMA of each indicator were calculated. From these calculations, benchmarking was performed with two other studies: PBIL (SBPC and Controllab) and IFCC (working group on patient safety and laboratory errors). A total of 5,541 errors were tracked in the 14 indicators, and 12 of these Instituto Nacional de Câncer (INCA) indicators were, in the year 2019, with a higher or equal behavior when compared to the other two studies (PBIL and IFCC). Hemolysis and fibrin after centrifugation were the indicators with the worst behavior and should have a greater focus for correction by the laboratory teams involved in this process. The Pre-analytical Error Management Manual was prepared in order to standardize processes and improve indicators below the desired level and maintain the quality of indicators that are at minimally acceptable levels. Continuous monitoring, coverage of all sectors of the laboratory and expansion of indicators tracked is essential to guarantee the quality of service provided by the laboratory and patient safety. |
Palavras-chave: | Erros laboratoriais Erros pré-analíticos Garantia da segurança do paciente Erros de diagnóstico Benchmarking (Administração) Segurança do Paciente Garantia da qualidade dos cuidados de saúde Doenças - Diagnóstico - Manuais de laboratório Hospital do Câncer I - Administração Laboratory errors Pre-analytical errors Benchmarking Patient quality assurance |
Área(s) do CNPq: | CIENCIAS BIOLOGICAS::BIOLOGIA GERAL |
Idioma: | por |
País: | Brasil |
Instituição: | Universidade do Estado do Rio de Janeiro |
Sigla da instituição: | UERJ |
Departamento: | Centro Biomédico::Instituto de Biologia Roberto Alcantara Gomes |
Programa: | Programa de Pós-Graduação em Saúde, Medicina Laboratorial e Tecnologia Forense |
Citação: | FERREIRA, Raphael Gialluisi da Silva Sá Ferreira. Identificação de não conformidades pré-analíticas do laboratório de patologia clínica do Hospital do Câncer I. 2022. 83 f. Dissertação (Mestrado em Saúde, Medicina Laboratorial e Tecnologia Forense) – Instituto de Biologia Roberto Alcântara Gomes, Universidade do Estado do Rio de Janeiro, Rio de Janeiro, 2022. |
Tipo de acesso: | Acesso Aberto |
URI: | http://www.bdtd.uerj.br/handle/1/17974 |
Data de defesa: | 18-Abr-2022 |
Aparece nas coleções: | Mestrado Profissional em Saúde, Medicina Laboratorial e Tecnologia Forense |
Arquivos associados a este item:
Arquivo | Descrição | Tamanho | Formato | |
---|---|---|---|---|
Dissertação - Raphael Gialluisi da Silva Sá Ferreira - 2022 - Completa.pdf | 1,62 MB | Adobe PDF | Baixar/Abrir Pré-Visualizar |
Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.