Compartilhamento |
![]() ![]() |
Use este identificador para citar ou linkar para este item:
http://www.bdtd.uerj.br/handle/1/23762
Tipo do documento: | Dissertação |
Título: | Avaliação da ultrassonografia ultraportátil à beira do leito, como fator preditivo de hipotensão em pacientes sob terapia renal substitutiva |
Título(s) alternativo(s): | Assessment of ultraportable bedside ultrasound, as a predictive factor of hypotension in patients undergoing renal replacement therapy |
Autor: | Soares, Débora Miguel ![]() |
Primeiro orientador: | Suassuna, José Hermógenes Rocco |
Primeiro coorientador: | Mendes, Renata de Souza |
Primeiro membro da banca: | Alves, Rogério Lopes Rufino |
Segundo membro da banca: | Sales, Ana Luiza Ferreira |
Terceiro membro da banca: | Maccariello, Elizabeth Regina |
Resumo: | A presença de hipotensão na hemodiálise é algo frequente e associada à menor eficiência do procedimento e à maior letalidade. A taxa de ultrafiltração é realizada para reduzir a sobrecarga hídrica, uma vez que esta, sabidamente, se associa à maior risco de injúria renal aguda e à maior letalidade na população dos pacientes em terapia intensiva. Desta forma, a avaliação da sobrecarga hídrica no paciente grave é desafiadora, pois os sinais e sintomas clínicos tem baixa sensibilidade. A avaliação pulmonar e da veia cava inferior com ultrassonografia têm sido cada vez mais realizada nos pacientes com injúria renal aguda de forma a melhor avaliar fluidorespossividade e fluidotolerância e prever com boa acurácia quais se beneficiam de uma maior ou menor ultrafiltração, minimizando a chance de instabilidade hemodinâmica durante o procedimento. Uma nova tecnologia de ultrassonografia ultraportátil, a tecnologia ultrasound-on-chip Butterfly IQ, permite a avaliação repetida de parâmetros múltiplos do paciente durante o curso da terapia renal substitutiva, podendo servir como instrumento para reavaliação da ultrafiltração inicialmente programada antes do desenvolvimento de hipotensão, evitando a interrupção do método por instabilidade e permitindo a modificação da ultrafiltração inicialmente definida. Desta forma, o objetivo dessa investigação foi avaliar de forma seriada parâmetros de ultrassonografia pulmonar (linhas B) e a dinâmica da variação do diâmetro da veia cava inferior em diferentes momentos antes do início e após o início da terapia renal substitutiva (30 minutos e 60 minutos) e correlacionar os achados com o desenvolvimento de hipotensão intradialítica (PAM < 60) e/ou interrupção do método. A tecnologia ultraportátil apresentou boa correlação com a ultrassonografia tradicional e o uso da avaliação da dinâmica da Veia cava demonstrou-se ferramenta útil em prever de forma precoce a hipotensão durante o procedimento dialítico. |
Abstract: | The presence of hypotension during hemodialysis is common and associated with lower efficiency of the procedure and greater lethality. The ultrafiltration rate is performed to reduce water overload, as this is known to be associated with a greater risk of acute kidney injury and greater lethality in the intensive care patient population. However, the assessment of fluid overload in critically ill patients is challenging, as pulmonary congestion is poorly correlated with clinical signs. Pulmonary and inferior vena cava evaluation with ultrasound has been increasingly performed in patients with acute kidney injury to better assess the patient's volume status and predict with good accuracy which one’s benefit from greater or lesser ultrafiltration, minimizing the chance of hemodynamic instability during the procedure. A new ultraportable ultrasound technology, the Butterfly IQ ultrasound-on-chip technology, allows the repeated assessment of multiple patient parameters during renal replacement therapy, and can serve as an instrument for reevaluating the ultrafiltration initially programmed before the development of hypotension, avoiding interruption of the method due to instability, and allowing modification of the initially defined ultrafiltration. Therefore, the objective of this investigation was to serially evaluate lung ultrasound parameters (B lines) and the dynamics of variation in the diameter of the inferior vena cava at different times before the start and after the start of renal replacement therapy (30 minutes and 60 minutes) and correlate the findings with the development of intradialytic hypotension (MAP < 60) and/or interruption of the method. The evaluations were carried out after validating the instrument, which showed similar accuracy compared to conventional ultrasound. Ultraportable technology showed good correlation with traditional ultrasound, and the use of Vena Cava dynamics assessment proved to be a useful tool in early predicting hypotension during the dialysis procedure. |
Palavras-chave: | POCUS Hemodiálise IRA Hipotensão intradialítica Volemia Hemodialysis AKI Intradialytic hypotension Hipotensão – Prevenção e controle Terapia de substituição renal – Métodos Ultrassonografia – Métodos Veia cava inferior – Diagnóstico por imagem |
Área(s) do CNPq: | CIENCIAS DA SAUDE::MEDICINA::CLINICA MEDICA::NEFROLOGIA |
Idioma: | por |
País: | Brasil |
Instituição: | Universidade do Estado do Rio de Janeiro |
Sigla da instituição: | UERJ |
Departamento: | Centro Biomédico::Faculdade de Ciências Médicas |
Programa: | Programa de Pós-Graduação em Ciências Médicas |
Citação: | SOARES, Débora Miguel. Avaliação da ultrassonografia ultraportátil à beira do leito, como fator preditivo de hipotensão em pacientes sob terapia renal substitutiva. 2024. 101 f. Dissertação (Mestrado em Ciências Médicas) – Faculdade de Ciências Médicas, Universidade do Estado do Rio de Janeiro, Rio de Janeiro, 2024. |
Tipo de acesso: | Acesso Aberto |
URI: | http://www.bdtd.uerj.br/handle/1/23762 |
Data de defesa: | 11-Dez-2024 |
Aparece nas coleções: | Mestrado em Ciências Médicas |
Arquivos associados a este item:
Arquivo | Descrição | Tamanho | Formato | |
---|---|---|---|---|
Dissertação - Débora Miguel Soares - 2024 - Completa.pdf | 5,73 MB | Adobe PDF | Baixar/Abrir Pré-Visualizar | |
Termo - Débora Miguel Soares - 2025.pdf | 279,91 kB | Adobe PDF | Baixar/Abrir Pré-Visualizar Solictar uma cópia | |
CRN - Débora Miguel Soares - 2025.pdf | 188,7 kB | Adobe PDF | Baixar/Abrir Pré-Visualizar Solictar uma cópia |
Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.